Centralite 3156105
Model | 3156105 |
Vendor | Centralite |
Description | HA thermostat |
Exposes | battery, temperature_setpoint_hold, climate (occupied_heating_setpoint, local_temperature, system_mode, running_state, fan_mode, occupied_cooling_setpoint), linkquality |
Picture |
Options
How to use device type specific configuration
thermostat_unit
: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius
,fahrenheit
Exposes
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Temperature setpoint hold (binary)
Prevent changes. false
= run normally. true
= prevent from making changes.. Value can be found in the published state on the temperature_setpoint_hold
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"temperature_setpoint_hold": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_setpoint_hold": NEW_VALUE}
. If value equals true
temperature setpoint hold is ON, if false
OFF.
Climate
This climate device supports the following features: occupied_heating_setpoint
, local_temperature
, system_mode
, running_state
, fan_mode
, occupied_cooling_setpoint
.
occupied_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_heating_setpoint": VALUE}
whereVALUE
is the °C between7
and30
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_heating_setpoint": ""}
.occupied_cooling_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_cooling_setpoint": VALUE}
whereVALUE
is the °C between7
and30
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_cooling_setpoint": ""}
.local_temperature
: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"local_temperature": ""}
.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:off
,heat
,cool
,emergency_heating
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"system_mode": ""}
.running_state
: The current running state. Possible values are:idle
,heat
,cool
,fan_only
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"running_state": ""}
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.