Iluminize 511.324
Model | 511.324 |
Vendor | Iluminize |
Description | Zigbee handheld remote CCT 4 channels |
Exposes | battery, action, action_group, action_transition_time, action_step_size, action_rate, linkquality |
Picture |
Options
How to use device type specific configuration
simulated_brightness
: Simulate a brightness value. If this device provides a brightness_move_up or brightness_move_down action it is possible to specify the update interval and delta. The action_brightness_delta indicates the delta for each interval. Example:
simulated_brightness:
delta: 20 # delta per interval, default = 20
interval: 200 # interval in milliseconds, default = 200
Exposes
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Action (enum)
Triggered action (e.g. a button click). Value can be found in the published state on the action
property. It's not possible to read (/get
) or write (/set
) this value. The possible values are: color_move
, color_temperature_move
, hue_move
, brightness_step_up
, brightness_step_down
, recall_*
, on
, off
, toggle
, brightness_stop
, brightness_move_up
, brightness_move_down
, color_loop_set
, enhanced_move_to_hue_and_saturation
, hue_stop
.
Action group (numeric)
Shows the zigbee2mqtt group bound to the active data point EP(1-4).. Value can be found in the published state on the action_group
property. It's not possible to read (/get
) or write (/set
) this value.
Action transition time (numeric)
Value can be found in the published state on the action_transition_time
property. It's not possible to read (/get
) or write (/set
) this value.
Action step size (numeric)
Value can be found in the published state on the action_step_size
property. It's not possible to read (/get
) or write (/set
) this value.
Action rate (numeric)
Value can be found in the published state on the action_rate
property. It's not possible to read (/get
) or write (/set
) this value.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.