Schneider Electric 545D6306
Model | 545D6306 |
Vendor | Schneider Electric |
Description | LK FUGA Wiser wireless PIR with relay |
Exposes | switch (state), occupancy, illuminance_lux, illuminance, occupancy_timeout, linkquality |
Picture |
Options
How to use device type specific configuration
illuminance_lux_calibration
: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number.illuminance_calibration
: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.state_action
: State actions will also be published as 'action' when true (default false). The value must betrue
orfalse
no_occupancy_since
: Sends a message after the last time no occupancy (occupancy: false) was detected. When setting this for example to [10, 60] a{"no_occupancy_since": 10}
will be send after 10 seconds and a{"no_occupancy_since": 60}
after 60 seconds. The value must be a list of [object Object].
Exposes
Switch (l1 endpoint)
The current state of this switch is in the published state under the state_l1
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l1": "ON"}
, {"state_l1": "OFF"}
or {"state_l1": "TOGGLE"}
. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state_l1": ""}
.
On with timed off
When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time
to the payload which is the time in seconds the state should remain on. Additionally an off_wait_time
property can be added to the payload to specify the cooldown time in seconds when the switch will not answer to other on with timed off commands. Support depends on the switch firmware. Some devices might require both on_time
and off_wait_time
to work Examples : {"state" : "ON", "on_time": 300}
, {"state" : "ON", "on_time": 300, "off_wait_time": 120}
.
Occupancy (binary)
Indicates whether the device detected occupancy. Value can be found in the published state on the occupancy
property. It's not possible to read (/get
) or write (/set
) this value. If value equals true
occupancy is ON, if false
OFF.
Illuminance (lux) (numeric)
Measured illuminance in lux. Value can be found in the published state on the illuminance_lux
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is lx
.
Illuminance (numeric)
Raw measured illuminance. Value can be found in the published state on the illuminance
property. It's not possible to read (/get
) or write (/set
) this value.
Occupancy timeout (numeric)
Time in seconds after which occupancy is cleared after detecting it. Value can be found in the published state on the occupancy_timeout
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"occupancy_timeout": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"occupancy_timeout": NEW_VALUE}
. The minimal value is 0
and the maximum value is 3600
. The unit of this value is s
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.