AduroSmart 81868
Model | 81868 |
Vendor | AduroSmart |
Description | Siren |
Exposes | tamper, warning, max_duration, alarm, linkquality |
Picture |
Exposes
Tamper (binary)
Indicates whether the device is tampered. Value can be found in the published state on the tamper
property. It's not possible to read (/get
) or write (/set
) this value. If value equals true
tamper is ON, if false
OFF.
Warning (composite)
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"warning": {"mode": VALUE, "level": VALUE, "strobe_level": VALUE, "strobe": VALUE, "strobe_duty_cycle": VALUE, "duration": VALUE}}
mode
(enum): Mode of the warning (sound effect) allowed values:stop
,burglar
,fire
,emergency
,police_panic
,fire_panic
,emergency_panic
level
(enum): Sound level allowed values:low
,medium
,high
,very_high
strobe_level
(enum): Intensity of the strobe allowed values:low
,medium
,high
,very_high
strobe
(binary): Turn on/off the strobe (light) during warning allowed values:true
orfalse
strobe_duty_cycle
(numeric): Length of the flash cycle max value is 10duration
(numeric): Duration in seconds of the alarm unit is s
Max duration (numeric)
Duration of Siren. Value can be found in the published state on the max_duration
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"max_duration": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"max_duration": NEW_VALUE}
. The minimal value is 0
and the maximum value is 600
. The unit of this value is s
.
Alarm (binary)
Manual start of siren. Value will not be published in the state. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"alarm": NEW_VALUE}
. If value equals ON
alarm is ON, if OFF
OFF.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.