SMaBiT (Bitron Video) AV2010/32
Model | AV2010/32 |
Vendor | SMaBiT (Bitron Video) |
Description | Wireless wall thermostat with relay |
Exposes | climate (occupied_heating_setpoint, local_temperature, system_mode, running_state, local_temperature_calibration, control_sequence_of_operation), keypad_lockout, hysteresis, battery, battery_low, linkquality |
Picture |
Notes
Heating or cooling
This thermostat can work in a heating or cooling mode. You can switch between them by setting control_sequence_of_operation
to either 'heating_only' (default after factory reset) or 'cooling_only'.
The exposed data will adapt dynamically, but it will require a Zigbee2MQTT restart before it gets updated after changing control_sequence_of_operation
.
Options
How to use device type specific configuration
thermostat_unit
: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius
,fahrenheit
legacy
: Set to false to disable the legacy integration (highly recommended), will change structure of the published payload (default true). The value must betrue
orfalse
Exposes
Climate
This climate device supports the following features: occupied_heating_setpoint
, local_temperature
, system_mode
, running_state
, local_temperature_calibration
, control_sequence_of_operation
.
occupied_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_heating_setpoint": VALUE}
whereVALUE
is the °C between7
and30
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_heating_setpoint": ""}
.local_temperature
: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"local_temperature": ""}
.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:off
,heat
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"system_mode": ""}
.running_state
: The current running state. Possible values are:idle
,heat
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"running_state": ""}
.local_temperature_calibration
: Offset to add/subtract to the local temperature. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"local_temperature_calibration": VALUE}.
To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"local_temperature": ""}
.The minimal value is-12.8
and the maximum value is12.7
with a step size of0.1
.
Keypad lockout (enum)
Enables/disables physical input on the device. Value can be found in the published state on the keypad_lockout
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"keypad_lockout": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"keypad_lockout": NEW_VALUE}
. The possible values are: unlock
, lock1
, lock2
.
Hysteresis (composite)
Set thermostat hysteresis low and high trigger values. (1 = 0.01ºC). Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"hysteresis": {"low": VALUE, "high": VALUE}}
To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"hysteresis": ""}
.
low
(numeric)high
(numeric)
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"battery": ""}
. It's not possible to write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Battery low (binary)
Indicates if the battery of this device is almost empty. Value can be found in the published state on the battery_low
property. It's not possible to read (/get
) or write (/set
) this value. If value equals true
battery low is ON, if false
OFF.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.