EFEKTA EFEKTA_T1_v2_LR
Model | EFEKTA_T1_v2_LR |
Vendor | EFEKTA |
Description | Temperature sensors with a signal amplifier. External DS18b20 sensor. Simple Thermostat. |
Exposes | identify, temperature, battery, voltage, battery_low, reading_interval, tx_radio_power, smart_sleep, uptime, resolution, config_report_enable, comparison_previous_data, enable_temperature, invert_logic_temperature, high_temperature, low_temperature |
Picture | ![]() |
Options
How to use device type specific configuration
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
identify_timeout
: Sets the duration of the identification procedure in seconds (i.e., how long the device would flash).The value ranges from 1 to 30 seconds (default: 3). The value must be a number with a minimum value of1
and with a with a maximum value of30
Exposes
Identify (enum)
Initiate device identification. Value will not be published in the state. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"identify": NEW_VALUE}
. The possible values are: identify
.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is °C
.
Battery (numeric)
Remaining battery in %. Value can be found in the published state on the battery
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"battery": ""}
. It's not possible to write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Voltage (numeric)
Reported battery voltage in millivolts. Value can be found in the published state on the voltage
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"voltage": ""}
. It's not possible to write (/set
) this value. The unit of this value is mV
.
Battery low (binary)
Empty battery indicator. Value can be found in the published state on the battery_low
property. It's not possible to read (/get
) or write (/set
) this value. If value equals true
battery low is ON, if false
OFF.
Reading interval (numeric)
Setting the sensor reading interval in seconds, by default 30 seconds. Value can be found in the published state on the reading_interval
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"reading_interval": NEW_VALUE}
. The minimal value is 10
and the maximum value is 360
. The unit of this value is sec
.
Tx radio power (enum)
Set TX Radio Power, dbm. Value can be found in the published state on the tx_radio_power
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"tx_radio_power": NEW_VALUE}
. The possible values are: 4dbm
, 19dbm
.
Smart sleep (binary)
Enable Smart Sleep, short wakeup every 7 seconds. Value can be found in the published state on the smart_sleep
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"smart_sleep": NEW_VALUE}
. If value equals ON
smart sleep is ON, if OFF
OFF.
Uptime (numeric)
Uptime. Value can be found in the published state on the uptime
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is Hours
.
Resolution (enum)
Set Bit resolution DS18B20. Value can be found in the published state on the resolution
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"resolution": NEW_VALUE}
. The possible values are: 9 bit
, 10 bit
, 11 bit
, 12 bit
.
Config report enable (binary)
Enable reporting based on reporting configuration. Value can be found in the published state on the config_report_enable
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"config_report_enable": NEW_VALUE}
. If value equals ON
config report enable is ON, if OFF
OFF.
Comparison previous data (binary)
Enable сontrol of comparison with previous data. Value can be found in the published state on the comparison_previous_data
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"comparison_previous_data": NEW_VALUE}
. If value equals ON
comparison previous data is ON, if OFF
OFF.
Enable temperature (binary)
Enable Temperature Control. Value can be found in the published state on the enable_temperature
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"enable_temperature": NEW_VALUE}
. If value equals ON
enable temperature is ON, if OFF
OFF.
Invert logic temperature (binary)
Invert Logic Temperature Control. Value can be found in the published state on the invert_logic_temperature
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"invert_logic_temperature": NEW_VALUE}
. If value equals ON
invert logic temperature is ON, if OFF
OFF.
High temperature (numeric)
Setting High Temperature Border. Value can be found in the published state on the high_temperature
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"high_temperature": NEW_VALUE}
. The minimal value is -50
and the maximum value is 120
. The unit of this value is °C
.
Low temperature (numeric)
Setting Low Temperature Border. Value can be found in the published state on the low_temperature
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"low_temperature": NEW_VALUE}
. The minimal value is -50
and the maximum value is 120
. The unit of this value is °C
.