HEIMAN HS3AQ
Model | HS3AQ |
Vendor | HEIMAN |
Description | Smart air quality monitor |
Exposes | co2, battery, humidity, temperature, linkquality |
Picture |
Notes
The base HS3AQ model does not have Zigbee, the Zigbee versions of this device are HS3AQ-TY(ZTU) and HS3AQ-EFA
Options
How to use device type specific configuration
co2_calibration
: Calibrates the co2 value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
Exposes
CO2 (numeric)
The measured CO2 (carbon dioxide) value. Value can be found in the published state on the co2
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is ppm
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is °C
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.