ShinaSystem ISM300Z3
Model | ISM300Z3 |
Vendor | ShinaSystem |
Description | SiHAS IOT smart inner switch 3 gang |
Exposes | switch (state), operation_mode, rf_pairing, switch_3way_mode, linkquality |
Picture |
Options
How to use device type specific configuration
state_action
: State actions will also be published as 'action' when true (default false). The value must betrue
orfalse
Exposes
Switch (l1 endpoint)
The current state of this switch is in the published state under the state_l1
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l1": "ON"}
, {"state_l1": "OFF"}
or {"state_l1": "TOGGLE"}
. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state_l1": ""}
.
On with timed off
When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time
to the payload which is the time in seconds the state should remain on. Additionally an off_wait_time
property can be added to the payload to specify the cooldown time in seconds when the switch will not answer to other on with timed off commands. Support depends on the switch firmware. Some devices might require both on_time
and off_wait_time
to work Examples : {"state" : "ON", "on_time": 300}
, {"state" : "ON", "on_time": 300, "off_wait_time": 120}
.
Switch (l2 endpoint)
The current state of this switch is in the published state under the state_l2
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l2": "ON"}
, {"state_l2": "OFF"}
or {"state_l2": "TOGGLE"}
. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state_l2": ""}
.
On with timed off
When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time
to the payload which is the time in seconds the state should remain on. Additionally an off_wait_time
property can be added to the payload to specify the cooldown time in seconds when the switch will not answer to other on with timed off commands. Support depends on the switch firmware. Some devices might require both on_time
and off_wait_time
to work Examples : {"state" : "ON", "on_time": 300}
, {"state" : "ON", "on_time": 300, "off_wait_time": 120}
.
Switch (l3 endpoint)
The current state of this switch is in the published state under the state_l3
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state_l3": "ON"}
, {"state_l3": "OFF"}
or {"state_l3": "TOGGLE"}
. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state_l3": ""}
.
On with timed off
When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time
to the payload which is the time in seconds the state should remain on. Additionally an off_wait_time
property can be added to the payload to specify the cooldown time in seconds when the switch will not answer to other on with timed off commands. Support depends on the switch firmware. Some devices might require both on_time
and off_wait_time
to work Examples : {"state" : "ON", "on_time": 300}
, {"state" : "ON", "on_time": 300, "off_wait_time": 120}
.
Operation mode (enum, l1 endpoint)
switch type: "auto" - toggle by S/W, "push" - for momentary S/W, "latch" - sync S/W.. Value can be found in the published state on the operation_mode_l1
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"operation_mode_l1": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"operation_mode_l1": NEW_VALUE}
. The possible values are: auto
, push
, latch
.
Rf pairing (enum, l1 endpoint)
Enable RF pairing mode each button l1, l2, l3. It is supported only in repeat mode.. Value can be found in the published state on the rf_pairing_l1
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"rf_pairing_l1": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"rf_pairing_l1": NEW_VALUE}
. The possible values are: none
, l1
, l2
, l3
.
Switch 3way mode (enum, l1 endpoint)
If the 3-way switch setting is enabled, the 1st and 3rd switches are used. At this time, connect the remote switch to SW3.. Value can be found in the published state on the switch_3way_mode_l1
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"switch_3way_mode_l1": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"switch_3way_mode_l1": NEW_VALUE}
. The possible values are: disable
, enable
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.