Nyce NCZ-3041-HA
Model | NCZ-3041-HA |
Vendor | Nyce |
Description | Wall motion sensor |
Exposes | occupancy, humidity, temperature, battery, battery_low, tamper, linkquality |
Picture |
Options
How to use device type specific configuration
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
no_occupancy_since
: Sends a message after the last time no occupancy (occupancy: false) was detected. When setting this for example to [10, 60] a{"no_occupancy_since": 10}
will be send after 10 seconds and a{"no_occupancy_since": 60}
after 60 seconds. The value must be a list of [object Object].
Exposes
Occupancy (binary)
Indicates whether the device detected occupancy. Value can be found in the published state on the occupancy
property. It's not possible to read (/get
) or write (/set
) this value. If value equals true
occupancy is ON, if false
OFF.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is °C
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Battery low (binary)
Indicates if the battery of this device is almost empty. Value can be found in the published state on the battery_low
property. It's not possible to read (/get
) or write (/set
) this value. If value equals true
battery low is ON, if false
OFF.
Tamper (binary)
Indicates whether the device is tampered. Value can be found in the published state on the tamper
property. It's not possible to read (/get
) or write (/set
) this value. If value equals true
tamper is ON, if false
OFF.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.