Develco SIRZB-111
Model | SIRZB-111 |
Vendor | Develco |
Description | Customizable siren |
Exposes | battery_low, test, warning, squawk, max_duration, alarm, temperature, battery, voltage, linkquality |
Picture |
Options
How to use device type specific configuration
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
Exposes
Battery low (binary)
Indicates if the battery of this device is almost empty. Value can be found in the published state on the battery_low
property. It's not possible to read (/get
) or write (/set
) this value. If value equals true
battery low is ON, if false
OFF.
Test (binary)
Indicates whether the device is being tested. Value can be found in the published state on the test
property. It's not possible to read (/get
) or write (/set
) this value. If value equals true
test is ON, if false
OFF.
Warning (composite)
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"warning": {"mode": VALUE, "level": VALUE, "strobe_level": VALUE, "strobe": VALUE, "strobe_duty_cycle": VALUE, "duration": VALUE}}
mode
(enum): Mode of the warning (sound effect) allowed values:stop
,burglar
,fire
,emergency
,police_panic
,fire_panic
,emergency_panic
level
(enum): Sound level allowed values:low
,medium
,high
,very_high
strobe_level
(enum): Intensity of the strobe allowed values:low
,medium
,high
,very_high
strobe
(binary): Turn on/off the strobe (light) during warning allowed values:true
orfalse
strobe_duty_cycle
(numeric): Length of the flash cycle max value is 10duration
(numeric): Duration in seconds of the alarm unit is s
Squawk (composite)
Can be set by publishing to zigbee2mqtt/FRIENDLY_NAME/set
with payload {"squawk": {"state": VALUE, "level": VALUE, "strobe": VALUE}}
state
(enum): Set Squawk state allowed values:system_is_armed
,system_is_disarmed
level
(enum): Sound level allowed values:low
,medium
,high
,very_high
strobe
(binary): Turn on/off the strobe (light) for Squawk allowed values:true
orfalse
Max duration (numeric)
Max duration of the siren. Value can be found in the published state on the max_duration
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"max_duration": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"max_duration": NEW_VALUE}
. The minimal value is 0
and the maximum value is 900
. The unit of this value is s
.
Alarm (binary)
Manual start of the siren. Value will not be published in the state. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"alarm": NEW_VALUE}
. If value equals START
alarm is ON, if OFF
OFF.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"temperature": ""}
. It's not possible to write (/set
) this value. The unit of this value is °C
.
Battery (numeric)
Remaining battery in %. Value can be found in the published state on the battery
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"battery": ""}
. It's not possible to write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Voltage (numeric)
Reported battery voltage in millivolts. Value can be found in the published state on the voltage
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"voltage": ""}
. It's not possible to write (/set
) this value. The unit of this value is mV
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255