Tuya SPM01V2.5
Model | SPM01V2.5 |
Vendor | Tuya |
Description | Smart energy monitor for 1P+N system |
Exposes | voltage, power, current, energy, produced_energy, power_factor, ac_frequency, linkquality |
Picture |
Options
How to use device type specific configuration
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number.voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number.current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
ac_frequency_calibration
: Calibrates the ac_frequency value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Voltage (numeric)
Measured electrical potential value. Value can be found in the published state on the voltage
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is V
.
Power (numeric)
Instantaneous measured power. Value can be found in the published state on the power
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is W
.
Current (numeric)
Instantaneous measured electrical current. Value can be found in the published state on the current
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is A
.
Energy (numeric)
Total forward active energy. Value can be found in the published state on the energy
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is kWh
.
Produced energy (numeric)
Total reverse active energy. Value can be found in the published state on the produced_energy
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is kWh
.
Power factor (numeric)
Instantaneous measured power factor. Value can be found in the published state on the power_factor
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
AC frequency (numeric)
Measured electrical AC frequency. Value can be found in the published state on the ac_frequency
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is Hz
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.