Tuya SPM02V2
Model | SPM02V2 |
Vendor | Tuya |
Description | Smart energy monitor for 3P+N system |
Exposes | voltage_a, voltage_b, voltage_c, power_a, power_b, power_c, current_a, current_b, current_c, energy, produced_energy, power_factor, power, ac_frequency, linkquality |
Picture |
Options
How to use device type specific configuration
energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
ac_frequency_calibration
: Calibrates the ac_frequency value (absolute offset), takes into effect on next report of device. The value must be a number.
Exposes
Voltage a (numeric)
Measured electrical potential value (phase A). Value can be found in the published state on the voltage_a
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is V
.
Voltage b (numeric)
Measured electrical potential value (phase B). Value can be found in the published state on the voltage_b
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is V
.
Voltage c (numeric)
Measured electrical potential value (phase C). Value can be found in the published state on the voltage_c
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is V
.
Power a (numeric)
Instantaneous measured power (phase A). Value can be found in the published state on the power_a
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is W
.
Power b (numeric)
Instantaneous measured power (phase B). Value can be found in the published state on the power_b
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is W
.
Power c (numeric)
Instantaneous measured power (phase C). Value can be found in the published state on the power_c
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is W
.
Current a (numeric)
Instantaneous measured electrical current (phase A). Value can be found in the published state on the current_a
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is A
.
Current b (numeric)
Instantaneous measured electrical current (phase B). Value can be found in the published state on the current_b
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is A
.
Current c (numeric)
Instantaneous measured electrical current (phase C). Value can be found in the published state on the current_c
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is A
.
Energy (numeric)
Total forward active energy. Value can be found in the published state on the energy
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is kWh
.
Produced energy (numeric)
Total reverse active energy. Value can be found in the published state on the produced_energy
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is kWh
.
Power factor (numeric)
Instantaneous measured power factor. Value can be found in the published state on the power_factor
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Power (numeric)
Instantaneous measured power. Value can be found in the published state on the power
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is W
.
AC frequency (numeric)
Measured electrical AC frequency. Value can be found in the published state on the ac_frequency
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is Hz
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.