Sunricher SR-ZG9033TH
Model | SR-ZG9033TH |
Vendor | Sunricher |
Description | Zigbee temperature and humidity sensor |
Exposes | battery, temperature, humidity, temperature_sensor_compensation, temperature_display_unit, humidity_sensor_compensation, linkquality |
Picture |
Options
How to use device type specific configuration
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
Exposes
Battery (numeric)
Remaining battery in %. Value can be found in the published state on the battery
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"battery": ""}
. It's not possible to write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"temperature": ""}
. It's not possible to write (/set
) this value. The unit of this value is °C
.
Humidity (numeric, 2 endpoint)
Measured relative humidity. Value can be found in the published state on the humidity_2
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"humidity_2": ""}
. It's not possible to write (/set
) this value. The unit of this value is %
.
Temperature sensor compensation (numeric, 1 endpoint)
Temperature sensor compensation (-5~+5°C). Value can be found in the published state on the temperature_sensor_compensation_1
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"temperature_sensor_compensation_1": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_sensor_compensation_1": NEW_VALUE}
. The minimal value is -5
and the maximum value is 5
. The unit of this value is °C
.
Temperature display unit (enum, 1 endpoint)
Temperature display unit. Value can be found in the published state on the temperature_display_unit_1
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"temperature_display_unit_1": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_display_unit_1": NEW_VALUE}
. The possible values are: celsius
, fahrenheit
.
Humidity sensor compensation (numeric, 2 endpoint)
Humidity sensor compensation (-5~+5%). Value can be found in the published state on the humidity_sensor_compensation_2
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"humidity_sensor_compensation_2": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"humidity_sensor_compensation_2": NEW_VALUE}
. The minimal value is -5
and the maximum value is 5
. The unit of this value is %
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.