Stelpro ST218
Model | ST218 |
Vendor | Stelpro |
Description | Ki convector, line-voltage thermostat |
Exposes | local_temperature, keypad_lockout, climate (occupied_heating_setpoint, local_temperature, system_mode, running_state, pi_heating_demand), linkquality |
Picture |
Options
How to use device type specific configuration
thermostat_unit
: Controls the temperature unit of the thermostat (default celsius). The value must be one ofcelsius
,fahrenheit
legacy
: Set to false to disable the legacy integration (highly recommended), will change structure of the published payload (default true). The value must betrue
orfalse
Exposes
Local temperature (numeric)
Current temperature measured on the device. Value can be found in the published state on the local_temperature
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"local_temperature": ""}
. It's not possible to write (/set
) this value. The unit of this value is °C
.
Keypad lockout (enum)
Enables/disables physical input on the device. Value can be found in the published state on the keypad_lockout
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"keypad_lockout": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"keypad_lockout": NEW_VALUE}
. The possible values are: unlock
, lock1
, lock2
.
Climate
This climate device supports the following features: occupied_heating_setpoint
, local_temperature
, system_mode
, running_state
, pi_heating_demand
.
occupied_heating_setpoint
: Temperature setpoint. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"occupied_heating_setpoint": VALUE}
whereVALUE
is the °C between5
and30
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"occupied_heating_setpoint": ""}
.pi_heating_demand
: Position of the valve (= demanded heat) where 0% is fully closed and 100% is fully open. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"pi_heating_demand": VALUE}
whereVALUE
is the % between0
and100
. Reading (/get
) this attribute is not possible.local_temperature
: Current temperature measured on the device (in °C). To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"local_temperature": ""}
.system_mode
: Mode of this device. To control publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"system_mode": VALUE}
whereVALUE
is one of:off
,auto
,heat
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"system_mode": ""}
.running_state
: The current running state. Possible values are:idle
,heat
. To read send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"running_state": ""}
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.