Keen Home SV02
Model | SV02 |
Vendor | Keen Home |
Description | Smart vent |
Exposes | cover (state, position), temperature, battery, pressure, linkquality |
Picture |
Options
How to use device type specific configuration
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
pressure_calibration
: Calibrates the pressure value (absolute offset), takes into effect on next report of device. The value must be a number.pressure_precision
: Number of digits after decimal point for pressure, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
invert_cover
: Inverts the cover position, false: open=100,close=0, true: open=0,close=100 (default false). The value must betrue
orfalse
Exposes
Cover
The current state of this cover is in the published state under the state
property (value is OPEN
or CLOSE
). To control this cover publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "OPEN"}
, {"state": "CLOSE"}
, {"state": "STOP"}
. To read the current state of this cover publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
. To change the position publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"position": VALUE}
where VALUE
is a number between 0
and 100
.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is °C
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Pressure (numeric)
The measured atmospheric pressure. Value can be found in the published state on the pressure
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is hPa
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.