Sercomm SZ-PIR04N
Model | SZ-PIR04N |
Vendor | Sercomm |
Description | PIR motion & temperature sensor |
Exposes | occupancy, tamper, illuminance, temperature, battery, voltage, linkquality |
Picture |
Options
How to use device type specific configuration
illuminance_calibration
: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
Exposes
Occupancy (binary)
Indicates whether the device detected occupancy. Value can be found in the published state on the occupancy
property. It's not possible to read (/get
) or write (/set
) this value. If value equals true
occupancy is ON, if false
OFF.
Tamper (binary)
Indicates whether the device is tampered. Value can be found in the published state on the tamper
property. It's not possible to read (/get
) or write (/set
) this value. If value equals true
tamper is ON, if false
OFF.
Illuminance (numeric)
Raw measured illuminance. Value can be found in the published state on the illuminance
property. It's not possible to read (/get
) or write (/set
) this value.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is °C
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Voltage (numeric)
Voltage of the battery in millivolts. Value can be found in the published state on the voltage
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is mV
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.