Tuya SZT06 V2.0
Model | SZT06 V2.0 |
Vendor | Tuya |
Description | Smart mini temperature and humidity sensor |
Exposes | temperature, humidity, identify, battery, voltage, linkquality |
Picture |
Options
How to use device type specific configuration
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
identify_timeout
: Sets the duration of the identification procedure in seconds (i.e., how long the device would flash).The value ranges from 1 to 30 seconds (default: 3). The value must be a number with a minimum value of1
and with a with a maximum value of30
Exposes
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"temperature": ""}
. It's not possible to write (/set
) this value. The unit of this value is °C
.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"humidity": ""}
. It's not possible to write (/set
) this value. The unit of this value is %
.
Identify (enum)
Initiate device identification. This device is asleep by default.You may need to wake it up first before sending the identify command.. Value will not be published in the state. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"identify": NEW_VALUE}
. The possible values are: identify
.
Battery (numeric)
Remaining battery in %. Value can be found in the published state on the battery
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"battery": ""}
. It's not possible to write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Voltage (numeric)
Reported battery voltage in millivolts. Value can be found in the published state on the voltage
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"voltage": ""}
. It's not possible to write (/set
) this value. The unit of this value is mV
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.