Tuya TS0601_soil_2
Model | TS0601_soil_2 |
Vendor | Tuya |
Description | Soil sensor |
Exposes | soil_moisture, temperature, temperature_f, temperature_sensitivity, humidity_sensitivity, temperature_alarm, humidity_alarm, max_temperature_alarm, min_temperature_alarm, max_humidity_alarm, min_humidity_alarm, schedule_periodic, battery, battery_state, linkquality |
Picture |
Options
How to use device type specific configuration
soil_moisture_calibration
: Calibrates the soil_moisture value (absolute offset), takes into effect on next report of device. The value must be a number.soil_moisture_precision
: Number of digits after decimal point for soil_moisture, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
Exposes
Soil moisture (numeric)
Measured soil moisture value. Value can be found in the published state on the soil_moisture
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Temperature (numeric)
Soil temperature. Value can be found in the published state on the temperature
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is -10
and the maximum value is 60
. The unit of this value is °C
.
Temperature f (numeric)
Soil temperature. Value can be found in the published state on the temperature_f
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 14
and the maximum value is 140
. The unit of this value is °F
.
Temperature sensitivity (numeric)
Temperature sensitivity. Value can be found in the published state on the temperature_sensitivity
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_sensitivity": NEW_VALUE}
. The minimal value is 0.3
and the maximum value is 1
. The unit of this value is °C
.
Humidity sensitivity (numeric)
Humidity sensitivity. Value can be found in the published state on the humidity_sensitivity
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"humidity_sensitivity": NEW_VALUE}
. The minimal value is 1
and the maximum value is 5
. The unit of this value is %
.
Temperature alarm (enum)
Temperature alarm state. Value can be found in the published state on the temperature_alarm
property. It's not possible to read (/get
) or write (/set
) this value. The possible values are: lower_alarm
, upper_alarm
, cancel
.
Humidity alarm (enum)
Humidity alarm state. Value can be found in the published state on the humidity_alarm
property. It's not possible to read (/get
) or write (/set
) this value. The possible values are: lower_alarm
, upper_alarm
, cancel
.
Max temperature alarm (numeric)
Upper temperature limit. Value can be found in the published state on the max_temperature_alarm
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"max_temperature_alarm": NEW_VALUE}
. The minimal value is 0
and the maximum value is 60
. The unit of this value is °C
.
Min temperature alarm (numeric)
Lower temperature limit. Value can be found in the published state on the min_temperature_alarm
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"min_temperature_alarm": NEW_VALUE}
. The minimal value is 0
and the maximum value is 60
. The unit of this value is °C
.
Max humidity alarm (numeric)
Upper humidity limit. Value can be found in the published state on the max_humidity_alarm
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"max_humidity_alarm": NEW_VALUE}
. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Min humidity alarm (numeric)
Lower humidity limit. Value can be found in the published state on the min_humidity_alarm
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"min_humidity_alarm": NEW_VALUE}
. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Schedule periodic (numeric)
Report sensitivity. Value can be found in the published state on the schedule_periodic
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"schedule_periodic": NEW_VALUE}
. The minimal value is 5
and the maximum value is 60
. The unit of this value is min
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Battery state (enum)
State of the battery. Value can be found in the published state on the battery_state
property. It's not possible to read (/get
) or write (/set
) this value. The possible values are: low
, medium
, high
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.