Schneider Electric WDE002334
Model | WDE002334 |
Vendor | Schneider Electric |
Description | Rotary dimmer |
Exposes | light (state, brightness, level_config), ballast_minimum_level, ballast_maximum_level, dimmer_mode, linkquality |
Picture |
Notes
Reduce flickering
To reduce flickering of LEDs behind the dimmer, try setting the dimmer_mode
to rl_led
but please beware that the allowed maximum load is 20 VA in this mode.
Options
How to use device type specific configuration
transition
: Controls the transition time (in seconds) of on/off, brightness, color temperature (if applicable) and color (if applicable) changes. Defaults to0
(no transition). The value must be a number with a minimum value of0
state_action
: State actions will also be published as 'action' when true (default false). The value must betrue
orfalse
Exposes
Light
This light supports the following features: state
, brightness
, level_config
.
state
: To control the state publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"state": "ON"}
,{"state": "OFF"}
or{"state": "TOGGLE"}
. To read the state send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"state": ""}
.brightness
: To control the brightness publish a message to topiczigbee2mqtt/FRIENDLY_NAME/set
with payload{"brightness": VALUE}
whereVALUE
is a number between0
and254
. To read the brightness send a message tozigbee2mqtt/FRIENDLY_NAME/get
with payload{"brightness": ""}
.
On with timed off
When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time
to the payload which is the time in seconds the state should remain on. Additionally an off_wait_time
property can be added to the payload to specify the cooldown time in seconds when the light will not answer to other on with timed off commands. Support depends on the light firmware. Some devices might require both on_time
and off_wait_time
to work Examples : {"state" : "ON", "on_time": 300}
, {"state" : "ON", "on_time": 300, "off_wait_time": 120}
.
Ballast minimum level (numeric)
Specifies the minimum light output of the ballast. Value can be found in the published state on the ballast_minimum_level
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"ballast_minimum_level": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"ballast_minimum_level": NEW_VALUE}
. The minimal value is 1
and the maximum value is 254
.
Ballast maximum level (numeric)
Specifies the maximum light output of the ballast. Value can be found in the published state on the ballast_maximum_level
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"ballast_maximum_level": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"ballast_maximum_level": NEW_VALUE}
. The minimal value is 1
and the maximum value is 254
.
Dimmer mode (enum)
Sets dimming mode to autodetect or fixed RC/RL/RL_LED mode (max load is reduced in RL_LED). Value can be found in the published state on the dimmer_mode
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"dimmer_mode": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"dimmer_mode": NEW_VALUE}
. The possible values are: auto
, rc
, rl
, rl_led
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.