RTX ZCR1-40EM
Model | ZCR1-40EM |
Vendor | RTX |
Description | Zigbee DIN energy meter |
Exposes | switch (state), ac_frequency, energy, power, power_factor, voltage, current, produced_energy, power_reactive, energy_reactive, total_energy, linkquality |
Picture |
Options
How to use device type specific configuration
ac_frequency_calibration
: Calibrates the ac_frequency value (absolute offset), takes into effect on next report of device. The value must be a number.energy_calibration
: Calibrates the energy value (percentual offset), takes into effect on next report of device. The value must be a number.energy_precision
: Number of digits after decimal point for energy, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
power_calibration
: Calibrates the power value (percentual offset), takes into effect on next report of device. The value must be a number.power_precision
: Number of digits after decimal point for power, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
voltage_calibration
: Calibrates the voltage value (percentual offset), takes into effect on next report of device. The value must be a number.voltage_precision
: Number of digits after decimal point for voltage, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
current_calibration
: Calibrates the current value (percentual offset), takes into effect on next report of device. The value must be a number.current_precision
: Number of digits after decimal point for current, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
Exposes
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
. It's not possible to read (/get
) this value.
AC frequency (numeric)
Measured electrical AC frequency. Value can be found in the published state on the ac_frequency
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is Hz
.
Energy (numeric)
Sum of consumed energy. Value can be found in the published state on the energy
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is kWh
.
Power (numeric)
Instantaneous measured power. Value can be found in the published state on the power
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is W
.
Power factor (numeric)
Instantaneous measured power factor. Value can be found in the published state on the power_factor
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Voltage (numeric)
Measured electrical potential value. Value can be found in the published state on the voltage
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is V
.
Current (numeric)
Instantaneous measured electrical current. Value can be found in the published state on the current
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is A
.
Produced energy (numeric)
Sum of produced energy. Value can be found in the published state on the produced_energy
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is kWh
.
Power reactive (numeric)
Instantaneous measured reactive power. Value can be found in the published state on the power_reactive
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is VAR
.
Energy reactive (numeric)
Sum of reactive energy. Value can be found in the published state on the energy_reactive
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is kVArh
.
Total energy (numeric)
Total consumed and produced energy. Value can be found in the published state on the total_energy
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is kWh
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.