HOBEIAN ZG-303Z
Model | ZG-303Z |
Vendor | HOBEIAN |
Description | Soil moisture sensor |
Exposes | water_warning, temperature, humidity, soil_moisture, temperature_unit, temperature_calibration, humidity_calibration, soil_calibration, temperature_sampling, soil_sampling, soil_warning, battery |
Picture | ![]() |
Options
How to use device type specific configuration
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
soil_moisture_calibration
: Calibrates the soil_moisture value (absolute offset), takes into effect on next report of device. The value must be a number.soil_moisture_precision
: Number of digits after decimal point for soil_moisture, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
Exposes
Water warning (enum)
Water shortage warning. Value can be found in the published state on the water_warning
property. It's not possible to read (/get
) or write (/set
) this value. The possible values are: none
, alarm
.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is °C
.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Soil moisture (numeric)
Measured soil moisture value. Value can be found in the published state on the soil_moisture
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Temperature unit (enum)
Temperature unit. Value can be found in the published state on the temperature_unit
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_unit": NEW_VALUE}
. The possible values are: celsius
, fahrenheit
.
Temperature calibration (numeric)
Temperature calibration. Value can be found in the published state on the temperature_calibration
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_calibration": NEW_VALUE}
. The minimal value is -2
and the maximum value is 2
. The unit of this value is °C
.
Humidity calibration (numeric)
Humidity calibration. Value can be found in the published state on the humidity_calibration
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"humidity_calibration": NEW_VALUE}
. The minimal value is -30
and the maximum value is 30
. The unit of this value is %
.
Soil calibration (numeric)
Soil Humidity calibration. Value can be found in the published state on the soil_calibration
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"soil_calibration": NEW_VALUE}
. The minimal value is -30
and the maximum value is 30
. The unit of this value is %
.
Temperature sampling (numeric)
Air temperature and humidity sampling. Value can be found in the published state on the temperature_sampling
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_sampling": NEW_VALUE}
. The minimal value is 5
and the maximum value is 3600
. The unit of this value is s
.
Soil sampling (numeric)
Soil humidity sampling. Value can be found in the published state on the soil_sampling
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"soil_sampling": NEW_VALUE}
. The minimal value is 5
and the maximum value is 3600
. The unit of this value is s
.
Soil warning (numeric)
Soil water shortage humidity value. Value can be found in the published state on the soil_warning
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"soil_warning": NEW_VALUE}
. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 100