Tuya ZY-M100-L
Model | ZY-M100-L |
Vendor | Tuya |
Description | Ceiling human breathe sensor |
Exposes | illuminance_lux, presence, target_distance, radar_sensitivity, minimum_range, maximum_range, detection_delay, fading_time, self_test, linkquality |
Picture |
Options
How to use device type specific configuration
illuminance_lux_calibration
: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number.
Exposes
Illuminance (lux) (numeric)
Measured illuminance in lux. Value can be found in the published state on the illuminance_lux
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is lx
.
Presence (binary)
Indicates whether the device detected presence. Value can be found in the published state on the presence
property. It's not possible to read (/get
) or write (/set
) this value. If value equals true
presence is ON, if false
OFF.
Target distance (numeric)
Distance to target. Value can be found in the published state on the target_distance
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is m
.
Radar sensitivity (numeric)
sensitivity of the radar. Value can be found in the published state on the radar_sensitivity
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"radar_sensitivity": NEW_VALUE}
. The minimal value is 0
and the maximum value is 9
.
Minimum range (numeric)
Minimum range. Value can be found in the published state on the minimum_range
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"minimum_range": NEW_VALUE}
. The minimal value is 0
and the maximum value is 9.5
. The unit of this value is m
.
Maximum range (numeric)
Maximum range. Value can be found in the published state on the maximum_range
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"maximum_range": NEW_VALUE}
. The minimal value is 0
and the maximum value is 9.5
. The unit of this value is m
.
Detection delay (numeric)
Detection delay. Value can be found in the published state on the detection_delay
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"detection_delay": NEW_VALUE}
. The minimal value is 0
and the maximum value is 10
. The unit of this value is s
.
Fading time (numeric)
Fading time. Value can be found in the published state on the fading_time
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"fading_time": NEW_VALUE}
. The minimal value is 0
and the maximum value is 1500
. The unit of this value is s
.
Self test (enum)
Self_test, possible results: checking, check_success, check_failure, others, comm_fault, radar_fault.. Value can be found in the published state on the self_test
property. It's not possible to read (/get
) or write (/set
) this value. The possible values are: checking
, check_success
, check_failure
, others
, comm_fault
, radar_fault
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.