Model | b-parasite |
Vendor | Custom devices (DiY) |
Description | b-parasite open source soil moisture sensor |
Exposes | temperature, humidity, battery, soil_moisture, illuminance_lux, linkquality |
Picture |
Notes
b-parasite open source soil moisture sensor
Options
How to use device type specific configuration
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
soil_moisture_calibration
: Calibrates the soil_moisture value (absolute offset), takes into effect on next report of device. The value must be a number.soil_moisture_precision
: Number of digits after decimal point for soil_moisture, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
illuminance_lux_calibration
: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number.
Exposes
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is °C
.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Soil moisture (numeric)
Measured soil moisture value. Value can be found in the published state on the soil_moisture
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Illuminance (lux) (numeric)
Measured illuminance in lux. Value can be found in the published state on the illuminance_lux
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is lx
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.