EFK is-thpl-zb
Model | is-thpl-zb |
Vendor | EFK |
Description | 4 in 1 multi sensor |
Exposes | occupancy, tamper, illuminance_lux, illuminance, temperature, humidity, battery, voltage, battery2, illuminance_calibration, temperature_calibration, humidity_calibration, reporting_enable, reporting_time, led_enable, pir_enable, sensitivity, keep_time, linkquality |
Picture |
Options
How to use device type specific configuration
illuminance_lux_calibration
: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number.illuminance_calibration
: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
Exposes
Occupancy (binary)
Indicates whether the device detected occupancy. Value can be found in the published state on the occupancy
property. It's not possible to read (/get
) or write (/set
) this value. If value equals true
occupancy is ON, if false
OFF.
Tamper (binary)
Indicates whether the device is tampered. Value can be found in the published state on the tamper
property. It's not possible to read (/get
) or write (/set
) this value. If value equals true
tamper is ON, if false
OFF.
Illuminance (lux) (numeric)
Measured illuminance in lux. Value can be found in the published state on the illuminance_lux
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is lx
.
Illuminance (numeric)
Raw measured illuminance. Value can be found in the published state on the illuminance
property. It's not possible to read (/get
) or write (/set
) this value.
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is °C
.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Voltage (numeric)
Voltage of the battery in millivolts. Value can be found in the published state on the voltage
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is mV
.
Battery2 (numeric)
Remaining battery 2 in %. Value can be found in the published state on the battery2
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is %
.
Illuminance calibration (numeric)
Illuminance calibration in lux. Value can be found in the published state on the illuminance_calibration
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"illuminance_calibration": NEW_VALUE}
. The minimal value is -20
and the maximum value is 20
.
Temperature calibration (numeric)
Temperature calibration (-2.0...2.0). Value can be found in the published state on the temperature_calibration
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_calibration": NEW_VALUE}
. The minimal value is -2
and the maximum value is 2
.
Humidity calibration (numeric)
Humidity calibration. Value can be found in the published state on the humidity_calibration
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"humidity_calibration": NEW_VALUE}
. The minimal value is -15
and the maximum value is 15
.
Reporting enable (binary)
Enable reporting. Value can be found in the published state on the reporting_enable
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"reporting_enable": NEW_VALUE}
. If value equals true
reporting enable is ON, if false
OFF.
Reporting time (numeric)
Reporting interval in minutes. Value can be found in the published state on the reporting_time
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"reporting_time": NEW_VALUE}
. The minimal value is 0
and the maximum value is 1440
.
Led enable (binary)
Enable LED. Value can be found in the published state on the led_enable
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"led_enable": NEW_VALUE}
. If value equals true
led enable is ON, if false
OFF.
Pir enable (binary)
Enable PIR sensor. Value can be found in the published state on the pir_enable
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"pir_enable": NEW_VALUE}
. If value equals true
pir enable is ON, if false
OFF.
Sensitivity (enum)
PIR sensor sensitivity. Value can be found in the published state on the sensitivity
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"sensitivity": NEW_VALUE}
. The possible values are: low
, medium
, high
.
Keep time (enum)
PIR keep time in seconds. Value can be found in the published state on the keep_time
property. It's not possible to read (/get
) this value. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"keep_time": NEW_VALUE}
. The possible values are: 0
, 30
, 60
, 120
, 240
, 480
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.