Schneider Electric 41E2PBSWMZ/356PB2MBTZ
Model | 41E2PBSWMZ/356PB2MBTZ |
Vendor | Schneider Electric |
Description | Wiser 40/300-Series module switch 2AX |
Exposes | switch (state), indicator_mode, linkquality |
Picture |
Notes
Pairing
Pair the switch to Zigbee2MQTT by pressing 3 times to enter pairing mode. When the LED is blinking in amber, it is in Zigbee pairing mode. If the LED indication is other than flashing amber, the device is in BLE mode.
Set the device to Zigbee mode by short pressing the push-button for 4 times and hold it for 20 secs, until, the red LED flashes in high frequency.
NOTE: Do not release the button when it flashes at a low frequency.
Release the button and wait until the LED blinks red and green or there is no LED indication.
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
state_action
: State actions will also be published as 'action' when true (default false). The value must betrue
orfalse
Exposes
Switch
The current state of this switch is in the published state under the state
property (value is ON
or OFF
). To control this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"state": "ON"}
, {"state": "OFF"}
or {"state": "TOGGLE"}
. To read the current state of this switch publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"state": ""}
.
On with timed off
When setting the state to ON, it might be possible to specify an automatic shutoff after a certain amount of time. To do this add an additional property on_time
to the payload which is the time in seconds the state should remain on. Additionally an off_wait_time
property can be added to the payload to specify the cooldown time in seconds when the switch will not answer to other on with timed off commands. Support depends on the switch firmware. Some devices might require both on_time
and off_wait_time
to work Examples : {"state" : "ON", "on_time": 300}
, {"state" : "ON", "on_time": 300, "off_wait_time": 120}
.
Indicator mode (enum, smart endpoint)
Set Indicator Mode for smart switch.. Value can be found in the published state on the indicator_mode_smart
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"indicator_mode_smart": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"indicator_mode_smart": NEW_VALUE}
. The possible values are: reverse_with_load
, consistent_with_load
, always_off
, always_on
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.