Aqara RTCGQ12LM
Model | RTCGQ12LM |
Vendor | Aqara |
Description | Motion sensor T1 |
Exposes | occupancy, illuminance_lux, illuminance, detection_interval, device_temperature, battery, voltage, power_outage_count, linkquality |
Picture | |
White-label | Yandex YNDX-00522 |
Notes
Adapter firmware
In order for this device to work, at least the following firmware is required on your adapter:
- CC2530/CC2531:
20211115
- CC1352/CC2652:
20211114
- CC2538:
20211222
- Conbee II:
0x26720700
Note that if you have already paired the device you will need to repair it after upgrading your adapter firmware.
Pairing
Press and hold the reset button on the device for +- 5 seconds (until the blue light starts blinking). After this the device will automatically join. If this doesn't work, try with a single short button press.
Note: When you fail to pair a device, try replacing the battery, this could solve the problem.
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
illuminance_lux_calibration
: Calibrates the illuminance_lux value (percentual offset), takes into effect on next report of device. The value must be a number.illuminance_calibration
: Calibrates the illuminance value (percentual offset), takes into effect on next report of device. The value must be a number.device_temperature_calibration
: Calibrates the device_temperature value (absolute offset), takes into effect on next report of device. The value must be a number.occupancy_timeout
: Time in seconds after which occupancy is cleared after detecting it (default is "detection_interval" + 2 seconds). The value must be equal to or greater than "detection_interval", and it can also be a fraction. The value must be a number with a minimum value of0
no_occupancy_since
: Sends a message the last time occupancy (occupancy: true) was detected. When setting this for example to [10, 60] a{"no_occupancy_since": 10}
will be send after 10 seconds and a{"no_occupancy_since": 60}
after 60 seconds. The value must be a list of [object Object].
Exposes
Occupancy (binary)
Indicates whether the device detected occupancy. Value can be found in the published state on the occupancy
property. It's not possible to read (/get
) or write (/set
) this value. If value equals true
occupancy is ON, if false
OFF.
Illuminance (lux) (numeric)
Measured illuminance in lux. Value can be found in the published state on the illuminance
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is lx
.
Illuminance (numeric)
Measured illuminance in lux. Value can be found in the published state on the illuminance
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is lx
.
Detection interval (numeric)
Time interval for detecting actions. Value can be found in the published state on the detection_interval
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"detection_interval": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"detection_interval": NEW_VALUE}
. The minimal value is 2
and the maximum value is 65535
. The unit of this value is s
.
Device temperature (numeric)
Temperature of the device. Value can be found in the published state on the device_temperature
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is °C
.
Battery (numeric)
Remaining battery in %, can take up to 24 hours before reported. Value can be found in the published state on the battery
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Voltage (numeric)
Voltage of the battery in millivolts. Value can be found in the published state on the voltage
property. It's not possible to read (/get
) or write (/set
) this value. The unit of this value is mV
.
Power outage count (numeric)
Number of power outages. Value can be found in the published state on the power_outage_count
property. It's not possible to read (/get
) or write (/set
) this value.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.