Tuya TS0201-z
Model | TS0201-z |
Vendor | Tuya |
Description | Temperature & Humidity Sensor (pvxx/ZigbeeTLc) |
Exposes | temperature, humidity, temperature_calibration, humidity_calibration, measurement_interval, battery, linkquality |
Picture |
OTA updates
This device supports OTA updates, for more information see OTA updates.
Options
How to use device type specific configuration
temperature_calibration
: Calibrates the temperature value (absolute offset), takes into effect on next report of device. The value must be a number.temperature_precision
: Number of digits after decimal point for temperature, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
humidity_calibration
: Calibrates the humidity value (absolute offset), takes into effect on next report of device. The value must be a number.humidity_precision
: Number of digits after decimal point for humidity, takes into effect on next report of device. This option can only decrease the precision, not increase it. The value must be a number with a minimum value of0
and with a with a maximum value of3
Exposes
Temperature (numeric)
Measured temperature value. Value can be found in the published state on the temperature
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"temperature": ""}
. It's not possible to write (/set
) this value. The unit of this value is °C
.
Humidity (numeric)
Measured relative humidity. Value can be found in the published state on the humidity
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"humidity": ""}
. It's not possible to write (/set
) this value. The unit of this value is %
.
Temperature calibration (numeric)
Temperature calibration, in 0.01° steps, default 0 °C.. Value can be found in the published state on the temperature_calibration
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"temperature_calibration": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"temperature_calibration": NEW_VALUE}
. The minimal value is -50
and the maximum value is 50
. The unit of this value is °C
.
Humidity calibration (numeric)
Humidity calibration, in 0.01% steps, default 0%.. Value can be found in the published state on the humidity_calibration
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"humidity_calibration": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"humidity_calibration": NEW_VALUE}
. The minimal value is -50
and the maximum value is 50
. The unit of this value is %
.
Measurement interval (numeric)
Measurement interval, default 10 seconds.. Value can be found in the published state on the measurement_interval
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"measurement_interval": ""}
. To write (/set
) a value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/set
with payload {"measurement_interval": NEW_VALUE}
. The minimal value is 3
and the maximum value is 255
. The unit of this value is s
.
Battery (numeric)
Remaining battery in %. Value can be found in the published state on the battery
property. To read (/get
) the value publish a message to topic zigbee2mqtt/FRIENDLY_NAME/get
with payload {"battery": ""}
. It's not possible to write (/set
) this value. The minimal value is 0
and the maximum value is 100
. The unit of this value is %
.
Linkquality (numeric)
Link quality (signal strength). Value can be found in the published state on the linkquality
property. It's not possible to read (/get
) or write (/set
) this value. The minimal value is 0
and the maximum value is 255
. The unit of this value is lqi
.